| Air demand and capacity | Specify required free air delivery (FAD) in m³/min or L/s at the stated discharge pressure. Indicative industrial demand bands at about 7–8 bar(g): 1–3 m³/min, 3–8 m³/min, 8–15 m³/min, and 15–30 m³/min. | Use measured or calculated simultaneous demand, including operating shifts, peak events, leakage, and planned expansion. Confirm the supplier’s FAD rating and test conditions. | Size to the real demand profile, not the sum of every machine’s nameplate consumption. Consider a suitably sized receiver or multiple compressors for varying loads. |
| Indicative motor-power range | For many oil-injected rotary screw packages around 7–8 bar(g), approximate pairings are: 1–3 m³/min: 7.5–22 kW; 3–8 m³/min: 22–45 kW; 8–15 m³/min: 45–90 kW; 15–30 m³/min: 90–200 kW. | Actual FAD per kW varies with pressure, compressor design, cooling conditions, and package configuration. | Use these ranges for initial screening only. Compare guaranteed FAD and specific power at the same pressure and operating conditions before selecting a unit. |
| Working pressure | Common package ratings include approximately 7.5–8 bar(g), 10 bar(g), and 13 bar(g). The required pressure should be defined at the point of use. | Include pressure losses through dryers, filters, piping, valves, and the distribution network. Check the minimum pressure required by the most demanding equipment. | Avoid choosing a higher pressure “just in case.” Raising system pressure increases energy use; about 7% more energy per additional bar is a commonly used rule of thumb, though actual results vary. |
| Fixed-speed or variable-speed control | Fixed-speed units suit steady, relatively constant demand. Variable-speed drive (VSD) units can suit applications with substantial, frequent demand variation. | Review the load profile over a representative production period, including minimum demand, peak demand, and hours at each load. | Request performance data across the expected operating range. VSD savings depend on the actual load profile and should not be assumed from motor rating alone. |
| Air quality specification | Define the required ISO 8573-1 purity class as a three-part code: particles:water:total oil. For example, Class 2:4:1 identifies separate targets for each contaminant type. | Different processes require different purity levels. Check product, process, instrument, and regulatory requirements rather than applying one class to the entire site by default. | State the required class at the point of use and identify whether it applies to the complete compressed-air system, including the compressor intake and downstream treatment. |
| Moisture control and dryer | Refrigerated dryers commonly provide a pressure dew point around +3°C. Desiccant dryers are commonly selected for lower dew points, such as −20°C or −40°C. | Consider ambient temperature, pipe exposure, outdoor lines, freezing risk, and the pressure dew point required by the process. | Match dryer type and capacity to inlet temperature, pressure, flow, and ambient conditions. Check that dryer pressure loss and purge or regeneration air are included in system sizing. |
| Oil carryover and filtration | For ISO 8573-1 total oil Class 1, the limit is ≤0.01 mg/m³ under the standard’s stated measurement basis. Required limits depend on the process. | Oil-injected compressors require appropriate downstream treatment where low oil content is needed. Filters do not remove every contaminant, and performance depends on correct sizing and maintenance. | Specify the complete required air-quality class and obtain documented performance for the compressor, filters, and dryer as a system. For oil-sensitive processes, assess whether oil-free compression is appropriate. |
| Cooling, ventilation, and installation | Check room temperature limits, ventilation requirements, heat rejection, service clearances, noise limits, and available electrical supply. | Confirm whether the package is air-cooled or water-cooled and account for the site’s ambient conditions and cooling-water availability, where applicable. | Request installation and heat-rejection data before finalizing the compressor room layout. Poor ventilation can reduce performance and reliability. |
| Reliability and backup capacity | Critical processes may require a standby unit or multiple compressors arranged to maintain supply during maintenance or an equipment fault. | Assess the consequence of a compressed-air interruption, maintenance access, available storage, and the time needed to restore production. | Choose redundancy based on risk and required availability. Confirm that controls can sequence multiple machines efficiently at changing demand. |
| Lifecycle cost and service | Compare purchase price, energy consumption, planned maintenance, consumables, treatment equipment, and expected service life. | Request energy and performance data at the intended pressure and load profile, plus maintenance intervals and required service access. | Evaluate total cost of ownership rather than initial price alone. Verify local service capability, parts availability, warranty terms, and monitoring options. |