| 1. General Medium-Voltage Distribution Transformer | 100–1,600 kVA | 6–20 kV / 0.4–0.69 kV | 50 or 60 Hz | AN or AF cooling; epoxy-resin encapsulated windings; commonly designed for 100% rated output under natural-air cooling | Indoor installation; optional metal enclosure; typical enclosure protection from IP00 to IP31 or higher depending on the project | Factories, warehouses, utility substations, apartment complexes, and general low-voltage distribution | Low fire risk, no liquid dielectric, reduced routine maintenance, and suitability for buildings where space and fire safety are important |
| 2. Industrial Motor and Process Transformer | 630–3,150 kVA | 6–13.8 kV / 0.4–6.6 kV | 50 or 60 Hz | AN/AF cooling; reinforced cast-resin insulation; optional temperature sensors and forced-air fans for overload or peak-load operation | Designed for frequent loading changes; commonly supplied with off-circuit tap links and increased mechanical strength for industrial fault conditions | Steel mills, mining plants, chemical facilities, cement plants, pumps, compressors, and large motor-control systems | Good resistance to moisture, dust, vibration, and short-circuit forces; suitable for demanding industrial duty cycles |
| 3. Commercial Building and Infrastructure Transformer | 315–1,600 kVA | 6–20 kV / 0.4–0.48 kV | 50 or 60 Hz | Natural-air cooling; low-flammability epoxy insulation; optional temperature monitoring and alarm contacts | Compact indoor package; enclosure and ventilation selected according to local electrical and building codes | Hospitals, hotels, airports, shopping centers, office towers, schools, and public infrastructure | Suitable for installation close to electrical loads; lower fire and spill risk than oil-filled equipment; quiet operation when properly specified |
| 4. Data Center and Mission-Critical Transformer | 1,000–2,500 kVA | 10–20 kV / 0.4–0.48 kV | 50 or 60 Hz | AN or AN/AF cooling; temperature sensors, digital monitoring, and optional redundant fan systems | Low-loss core design; high short-circuit withstand capability; compatible with automatic transfer, UPS, and generator systems | Data centers, telecommunications sites, financial facilities, emergency power systems, and other critical-load installations | High operational continuity, predictable thermal performance, reduced maintenance requirements, and improved installation flexibility indoors |
| 5. Solar Photovoltaic Step-Up Transformer | 1,000–3,150 kVA per unit | 0.4–0.8 kV / 10–35 kV | 50 or 60 Hz | AN/AF cooling; cast-resin windings selected for cyclic loading and outdoor or containerized installation conditions | Often integrated into a compact skid or power-conversion station; optional temperature monitoring, surge protection, and higher enclosure protection | Utility-scale solar farms, commercial rooftop clusters, battery-coupled photovoltaic systems, and microgrids | Handles daily load cycling, avoids oil leakage risk, and can be installed near inverters when local environmental and fire requirements allow |
| 6. Wind Power Collector Transformer | 1,600–5,000 kVA per unit | 0.69–1.0 kV / 20–36 kV | 50 or 60 Hz | AN/AF cooling; reinforced resin insulation; design may include enhanced vibration, thermal-cycling, and partial-discharge performance requirements | Compact dimensions for nacelle, tower-base, or collection-substation installation; corrosion protection selected for coastal or offshore environments | Onshore wind farms, offshore wind platforms, wind turbine nacelles, and renewable-energy collection networks | High mechanical strength, reduced fire load, resistance to humidity, and suitability for variable renewable generation profiles |
| 7. Harmonic-Resistant Converter and VFD Transformer | 500–2,500 kVA | 6–13.8 kV / 0.4–0.69 kV | 50 or 60 Hz | AN or AF cooling; thermal design accounts for additional losses caused by nonlinear loads; optional electrostatic shielding and temperature monitoring | Specified with suitable impedance, conductor arrangement, and harmonic-duty capability; protection and grounding must match the converter system | Variable-frequency drives, battery energy-storage systems, electric-vehicle charging hubs, rectifier systems, and industrial power electronics | Improved thermal management under distorted current, better compatibility with power-electronic loads, and reduced risk of premature insulation aging |