| Quality management | ISO 9001:2015 | Documented procedures covering design, purchasing, production, inspection, nonconformity control and corrective action. | Valid certificate, certification scope, recent audit record and quality-control procedure. |
| Aluminum profile specification | GB/T 5237.1 and GB/T 5237.6; EN 14024 for thermal-break profiles | Profile alloy, temper, dimensional tolerances, polyamide thermal barrier and mechanical assembly method are clearly defined. | Extrusion drawings, alloy and temper data, thermal-barrier dimensions, dimensional inspection records and sample sections. |
| Window and door product compliance | GB/T 8478; EN 14351-1 where applicable | The supplier provides product specifications, installation requirements, performance declarations and configuration limits for each system. | Technical data sheet, system catalogue, tested size range, hardware schedule and installation manual. |
| Thermal performance | ISO 10077-1/-2; EN 12412-2; project energy code | Whole-window Uw is calculated for the actual frame, glazing, spacer, size and configuration. A common energy-efficient reference target is Uw ≤ 1.8 W/m²·K; lower values require suitable glazing and warm-edge details. | Calculation report or laboratory test report showing frame Uf, glass Ug, spacer type and whole-window Uw. |
| Air permeability | EN 12207; test method EN 1026 | Class 4 is a strong reference target for many high-performance window applications, subject to project requirements and tested size. | Independent test report stating pressure sequence, specimen size, leakage result and classification. |
| Watertightness | EN 12208; test method EN 1027 | Class 9A is a demanding reference level for exposed façades, but the required class must match building height, exposure and drainage design. | Water-tightness report with test pressure, test duration, specimen dimensions, drainage details and failure observations. |
| Wind resistance | EN 12210; test method EN 12211; project structural code | Class C5 can be used as a high-performance reference, but the required pressure must be calculated from site wind speed, building height, exposure and window size. | Wind-load calculation, deflection limits, test report and maximum approved sash or frame dimensions. |
| Glass and safety configuration | EN 12600; EN 12150; EN 14449; applicable local safety-glazing requirements | Glass type, thickness, safety treatment, edge clearance, bite depth and drainage are specified for each opening size. | Glass build-up schedule, safety-glazing declaration, spacer details and approved glazing instructions. |
| Hardware and operating durability | EN 13126 series; EN 1191 and EN 12400 where applicable | Hardware load rating, corrosion protection, adjustment method, replacement availability and cycle performance are documented. | Hardware schedule, cycle-test report, corrosion classification, maintenance instructions and spare-parts policy. |
| Surface treatment | GB/T 5237.2 for anodizing; GB/T 5237.4 for powder coating; Qualicoat or equivalent project requirement where specified | Coating type, film thickness, color tolerance, pretreatment and corrosion-resistance requirements are controlled by documented inspection. | Coating test results, thickness records, color approval sample, pretreatment process and batch traceability. |
| Factory testing and inspection | ISO 9001 procedures; applicable GB/T and EN product-test methods | Incoming-material inspection, in-process checks, final dimensional inspection, functional testing and documented release approval are performed for every production batch. | Inspection and test plan, sample inspection records, calibration certificates and final inspection report. |
| Traceability | ISO 9001 documented-information controls | Profiles, glass, hardware, sealants and finished units can be traced to purchase batch, production date and inspection records. | Batch-number system, material certificates, production labels, packing records and nonconformity log. |
| Environmental and workplace controls | ISO 14001:2015; ISO 45001:2018 | Environmental aspects, waste handling, chemical management, worker safety and emergency procedures are managed through auditable systems. | Valid certificates, audit scope, waste-disposal records, chemical safety documentation and occupational-safety procedures. |
| Project engineering support | Project specifications, structural calculations and applicable building codes | The supplier can provide shop drawings, wind-load checks, interface details, sample approvals, method statements and installation guidance. | Design team qualifications, sample shop drawings, calculation template, revision-control procedure and site-support plan. |
| Warranty and after-sales service | Contract terms and project-specific warranty requirements | Warranty coverage clearly separates profiles, surface finish, insulating glass, hardware, sealants and installation workmanship, with defined response times. | Written warranty, exclusions, maintenance schedule, spare-parts commitment and claims-response procedure. |