| 1 | Precision Laboratory Profile | Reference testing, calibration benches, and metrology work | 0 to 1,000 kPa / 0 to 145 psi | ±0.05% FS | 0.01 kPa | Pa, kPa, bar, psi, MPa, kgf/cm² | Temperature-compensated digital pressure sensor | Peak capture, min/max, zero, tare, data logging | USB-C; optional Bluetooth Low Energy | IP65 | -10 to 50°C | Up to 120 hours of continuous use | ISO/IEC 17025 calibration recommended | Best accuracy class |
| 2 | Industrial Process Profile | Hydraulics, pneumatics, compressors, and process maintenance | 0 to 2,000 kPa / 0 to 290 psi | ±0.10% FS | 0.1 kPa | kPa, bar, psi, MPa | Strain-gauge pressure transducer | Alarm limits, peak hold, auto-off, timestamped readings | Bluetooth Low Energy | IP67 | -20 to 60°C | Approximately 80 hours | Calibration certificate available by request | Strong industrial choice |
| 3 | Automotive Service Profile | Passenger vehicles, motorcycles, workshops, and fleet checks | 0 to 700 kPa / 0 to 100 psi | ±0.25% FS | 0.1 psi | psi, bar, kPa, kgf/cm² | Digital piezoresistive sensor | Backlit display, programmable target, pressure release valve | Bluetooth Low Energy | IP54 | 0 to 45°C | Approximately 40 hours | Factory test report; verify traceability | Best for routine tire service |
| 4 | High-Pressure Hydraulic Profile | Hydraulic power units, heavy equipment, and pressure testing | 0 to 60 MPa / 0 to 8,700 psi | ±0.10% FS | 0.001 MPa | MPa, bar, psi, kPa | High-pressure stainless-steel diaphragm sensor | Peak pressure, leak-test timing, alarm thresholds, data export | USB-C; optional wireless module | IP67 | -20 to 70°C | Approximately 70 hours | ISO/IEC 17025 certificate preferred | Best for high-pressure work |
| 5 | HVAC/R Service Profile | Refrigeration systems, air-conditioning, and vacuum service | -100 to 5,000 kPa / -14.5 to 725 psi | ±0.25% FS | 0.01 bar | micron, Pa, kPa, bar, psi, MPa | Compound-range digital sensor | Vacuum mode, refrigerant presets, temperature compensation, logging | Bluetooth Low Energy | IP54 | -10 to 50°C | Approximately 50 hours | Calibration certificate recommended | Best HVAC versatility |
| 6 | Cleanroom and Gas Profile | Low-pressure gas lines, filtration, and ventilation systems | -10 to 10 kPa / -1.45 to 1.45 psi | ±0.10% FS | 0.001 kPa | Pa, kPa, mbar, inH₂O, inHg | Low-differential-pressure MEMS sensor | Differential mode, zero tracking, trend display, logging | USB-C; Bluetooth Low Energy | IP40 | 0 to 45°C | Approximately 60 hours | Traceable calibration required | Best low-pressure resolution |
| 7 | Outdoor Field-Service Profile | Utilities, construction equipment, and mobile maintenance | 0 to 4,000 kPa / 0 to 580 psi | ±0.25% FS | 1 kPa | kPa, bar, psi, MPa | Sealed piezoresistive sensor | Shock logging, auto-off, backlight, rechargeable battery | Bluetooth Low Energy | IP68 | -20 to 60°C | Approximately 100 hours | Verify calibration interval | Best environmental protection |
| 8 | Pneumatic Automation Profile | Factory air systems, actuators, and production-line checks | 0 to 1,600 kPa / 0 to 232 psi | ±0.25% FS | 0.1 kPa | kPa, bar, psi, MPa | Digital ceramic-capacitive sensor | Pass/fail limits, batch logging, zero correction, auto power-off | Bluetooth Low Energy | IP65 | -10 to 55°C | Approximately 90 hours | Factory calibration report | Best production-line workflow |
| 9 | Portable Data-Logging Profile | Audits, commissioning, preventive maintenance, and inspections | 0 to 2,500 kPa / 0 to 363 psi | ±0.20% FS | 0.1 kPa | Pa, kPa, bar, psi, MPa | Temperature-compensated piezoresistive sensor | Up to 10,000 records, time-stamped logs, CSV export, alarms | USB-C and Bluetooth Low Energy | IP65 | -10 to 50°C | Approximately 75 hours | Digital certificate preferred | Best record-keeping capability |
| 10 | General-Purpose Smart Profile | Workshop, laboratory support, education, and general maintenance | 0 to 1,000 kPa / 0 to 145 psi | ±0.25% FS | 0.1 kPa | kPa, bar, psi, MPa, kgf/cm² | Digital piezoresistive sensor | Peak hold, min/max, tare, backlight, auto-off | Bluetooth Low Energy | IP54 | 0 to 45°C | Approximately 45 hours | Confirm certificate scope | Best balanced option |