| Standard rating condition | Flow water: 75°C Return water: 65°C Room air: 20°C | A commonly used EN 442 reference condition for declaring radiator heat output. | Compare declared outputs only when they use the same temperature conditions. |
| Temperature difference, ΔT | ΔT = (flow temperature + return temperature) ÷ 2 − room temperature (75 + 65) ÷ 2 − 20 = 50 K | The mean water temperature is 70°C, which is 50 K above the 20°C room temperature. A temperature difference of 50 K is commonly written as ΔT50. | ΔT is a temperature difference; its numerical value is the same in kelvins and degrees Celsius. |
| Declared heat output | Watts (W) at the stated test condition | The output rating applies to the tested radiator configuration and stated operating conditions. | Check the complete model, dimensions, connection arrangement and output conditions—not just the radiator type. |
| Lower-temperature operation | Example condition: 55°C flow / 45°C return / 20°C room ΔT = (55 + 45) ÷ 2 − 20 = 30 K | This condition gives ΔT30, so the radiator’s output will generally be lower than its ΔT50 output. | For heat pumps or other low-temperature systems, request the output at the actual design temperatures. |
| Converting output between ΔT values | Q₂ = Q₁ × (ΔT₂ ÷ ΔT₁)n | Q is heat output; n is the radiator’s model-specific exponent. The exponent should come from the relevant product data or test information. | Do not assume one universal exponent for every radiator. Use the manufacturer’s published conversion data for the exact model. |
| System design and room sizing | Compare required room heat loss with radiator output at the system’s design temperatures. | A radiator’s nominal ΔT50 output alone does not establish whether it will heat a particular room adequately. | Allow for the building’s heat loss, local design conditions, pipework and control strategy. |
| Rating interpretation | EN 442 output ratings are test-condition-specific. | Actual installed output can differ when water temperatures, room conditions or installation details differ from the rating conditions. | For purchasing comparisons, request clear EN 442 documentation and output figures for the intended operating temperatures. |