| Construction sites | 30–500 kVA | Prime power | Diesel set; mobile trailer or weather-protected enclosure; typically three-phase, 380/220 V, 50 Hz | Suitable for temporary power where grid access is limited or unavailable, and can be relocated as work areas change. | Allow for motor starting current from pumps, compressors, cranes, and other equipment. Consider dust, vibration, and frequent load changes. |
| Commercial buildings | 100–1,000 kVA | Standby power | Stationary diesel set with automatic transfer switch (ATS) and an indoor or outdoor enclosure | Can supply selected building loads during a utility outage, including lighting, lifts, pumps, and essential services. | Define which loads are essential, check local noise and emissions requirements, and provide adequate ventilation and exhaust routing. |
| Data centers | 500–2,500 kVA per set | Standby power | Stationary diesel sets, often arranged in parallel with redundant capacity and automatic controls | Parallel systems can support high-demand critical loads and provide redundancy when designed for the facility’s power architecture. | Calculate the full critical load, UPS interaction, step-load response, redundancy target, fuel autonomy, and available installation space. |
| Hospitals and healthcare facilities | 200–1,500 kVA | Standby power | One or more stationary sets with ATS and circuits prioritized for essential services | Provides backup electricity for designated critical systems, such as emergency lighting, medical equipment, and essential ventilation. | Separate critical and non-critical loads, account for motor starting, and follow applicable electrical, fire, and healthcare requirements. |
| Telecommunications sites | 5–50 kVA | Prime or standby, depending on grid reliability | Compact diesel set, often paired with batteries and a rectifier system | Works as part of a backup-power arrangement for remote or unattended communications sites. | Consider remote monitoring, battery charging demand, site access, fuel delivery, ambient temperature, and maintenance intervals. |
| Agriculture and irrigation | 20–200 kVA | Prime power | Diesel set matched to irrigation pumps or other farm equipment | Provides an independent source of power for seasonal or off-grid agricultural operations. | Match the set to pump motor starting requirements, operating hours, water-pumping schedules, and expected load variation. |
| Mining and quarrying | 250–2,000 kVA | Prime power | Heavy-duty diesel set or synchronized multi-set installation | Can supply substantial loads at remote sites where utility power is unavailable or insufficient. | Allow for large motors and changing loads; assess altitude, temperature, dust protection, fuel logistics, and service access. |
| Events and temporary venues | 20–300 kVA | Temporary or standby power | Portable or trailer-mounted set, with distribution equipment suited to the event | Offers a flexible power source for temporary venues, outdoor productions, and short-term installations. | Estimate simultaneous demand, account for audio and lighting equipment, manage cable runs, and comply with site noise limits. |