| 1 | Ultraviolet B coverage | 280–315 nm | Spectral transmittance, T(λ), across the band; identify the scan interval and resolution. | UVB is a conventional ultraviolet wavelength region. UV filtering should be reported separately from blue-light filtering. |
| 2 | Ultraviolet A coverage | 315–400 nm | Spectral transmittance across the band, including the upper end near 400 nm. | UVA is conventionally defined as 315–400 nm. Different test methods may specify different reporting details. |
| 3 | Visible-light coverage | Approximately 380–780 nm | Full spectral-transmittance curve and any declared visible-light summary value. | This is a commonly used visible-range convention. The exact range used for a reported summary should be stated. |
| 4 | Blue-violet sub-band | 400–455 nm | Transmittance at selected wavelengths and the mean or integrated value for the stated band. | This sub-band is used in some blue-light discussions, but it is not a universal definition of “blue light.” |
| 5 | Blue-light band | 400–500 nm | Transmittance curve and a clearly defined band summary. | 400–500 nm is a commonly used operational band for blue-light comparisons; a report should disclose its chosen definition. |
| 6 | Spectral transmittance | T(λ) = transmitted spectral power ÷ incident spectral power × 100% | Transmittance in percent at each measured wavelength, with the instrument’s wavelength interval and resolution. | Lower transmittance at a wavelength means less light at that wavelength passes through the tested lens under the measurement conditions. |
| 7 | Unweighted band-average transmittance | For a continuous scan: average T(λ) over the declared band, such as 400–500 nm. | Report the band limits, averaging method, and resulting percentage. | An unweighted average treats wavelengths within the selected band equally. It is not interchangeable with a weighted value. |
| 8 | Selected-wavelength values | Example reporting points: 400, 420, 450, 480, and 500 nm. | Give T(λ) at each point, or state that values were interpolated from a measured spectrum. | These are suggested comparison points, not a claim that every standard requires this exact set. |
| 9 | Weighted blue-light transmittance | Weighted average of T(λ) using a disclosed spectral weighting function over a disclosed wavelength range. | Name the weighting function, wavelength limits, calculation method, and final percentage. | Weighted results depend on the selected function and range. They should not be compared directly when calculation methods differ. |
| 10 | Sample and test conditions | Record lens material, sample thickness, coating or tint, orientation, instrument, and test setup. | Identify the tested sample and provide the measurement method, calibration status, and any repeat measurements. | These details help make results reproducible. A generic “blue-light blocking” percentage without its wavelength range and method is incomplete. |