| 1 | Intended application | Identify whether the pipe is for process piping, water transmission, structural use, piling, boiler service, or line-pipe service. | Different applications require different product standards, testing, dimensions, and documentation. | State the service and applicable specification in the inquiry; do not describe the requirement only as “steel pipe.” |
| 2 | Fluid or material conveyed | Specify the contents, such as potable water, seawater, natural gas, crude oil, steam, chemicals, or slurry. | Fluid composition can affect corrosion, erosion, cleanliness, and material compatibility. | For corrosive or abrasive service, provide relevant composition data, solids content, and any known contaminants. |
| 3 | Operating pressure | Provide normal and maximum operating pressure, including design pressure and any pressure surges. | Pressure affects required wall thickness, connection selection, and the applicable design calculation. | Give pressure units and distinguish operating pressure from design pressure; have the final thickness verified to the governing code. |
| 4 | Operating temperature | State minimum, normal, and maximum metal or fluid temperatures, including start-up and shutdown conditions. | Temperature can influence allowable stress, toughness requirements, thermal expansion, and material suitability. | Report the full temperature range and identify whether low-temperature impact testing or elevated-temperature design checks are required. |
| 5 | Corrosion environment | Describe internal and external exposure, including chlorides, soil conditions, humidity, marine atmosphere, and chemical treatment. | Corrosion allowance, coating, lining, or a corrosion-resistant material may be needed depending on the service. | Specify whether the pipe will be buried, submerged, outdoors, or exposed to process chemicals, and define any coating or lining requirements. |
| 6 | Pipe size and wall thickness | Define nominal pipe size or outside diameter, required wall thickness or schedule, length, and dimensional tolerances. | Clear dimensions help prevent mismatches with fittings, supports, equipment, and installation drawings. | Reference the required dimensional standard and state whether dimensions are nominal or subject to a specified tolerance. |
| 7 | Material and grade | Identify the required material specification and grade, along with any supplementary requirements for toughness or chemistry. | Grade selection must suit the design conditions and the rules of the project’s governing standard. | Request material test certificates traceable to the supplied pipe and confirm that the stated grade is permitted for the intended service. |
| 8 | Manufacturing route and weld requirements | Define whether seamless or welded pipe is acceptable and identify any requirements for weld examination or heat treatment. | Manufacturing route and inspection requirements can affect availability, inspection planning, and project acceptance. | Specify the permitted manufacturing method and the required non-destructive examination in accordance with the project specification. |
| 9 | Installation and external loads | Describe above-ground, buried, underwater, or structural installation, as well as support spacing, bending, vibration, and external loads. | Installation conditions can govern wall thickness, coating, handling requirements, and pipe support design. | Provide route drawings or load information where relevant, and confirm requirements for field welding, bending, and end preparation. |
| 10 | Inspection, testing, and documentation | Set out required hydrostatic or other tests, dimensional checks, material traceability, inspection records, and certification. | Defined acceptance criteria reduce ambiguity during inspection and help ensure the delivered pipe meets project requirements. | List the governing standard, inspection level, test requirements, document package, marking, and any independent inspection needs. |