| 1. Match the motor to the load | Identify the load’s continuous power demand, starting load, and any short-duration peak demand. | 1.5 mechanical horsepower is approximately 1.12 kW of shaft output. Electrical input will be higher because of motor and drive losses. | Compare the load’s required shaft power with the motor’s rated output. Check the motor and drive specifications for permitted overload duration; do not assume a standard overload capacity. |
| 2. Check speed and torque together | Specify the required operating speed in rpm and the torque needed at that speed. | For 1.12 kW output, approximate rated torque is 3.6 N·m at 3,000 rpm or 7.1 N·m at 1,500 rpm, using T (N·m) = 9,550 × P (kW) ÷ speed (rpm). | Confirm that the motor and controller can provide the required torque across the full speed range. Available torque may decrease at higher speeds or outside the specified operating range. |
| 3. Define the duty cycle | Record daily operating hours, starts per hour, acceleration time, and whether the load runs continuously or intermittently. | S1 denotes continuous-duty operation at a constant load long enough to reach thermal equilibrium. Intermittent duty requires a defined cycle, including run and rest periods. | Choose a motor rated for the actual duty. Frequent starts, repeated acceleration, or sustained high torque can increase heating; verify the motor and drive ratings for the intended cycle. |
| 4. Verify the electrical supply and drive | Specify available AC or DC supply, voltage, phase, frequency where applicable, and the control method. | A brushless motor generally requires a compatible electronic controller. Rated voltage, current, commutation method, and controller limits must match the motor’s specifications. | Check supply compatibility, continuous and peak current limits, speed-control range, and protection features. Use the manufacturer’s wiring and controller requirements for the selected motor model. |
| 5. Account for installation and environment | Measure shaft, mounting, and available space; note ambient temperature, dust, moisture, vibration, and cooling conditions. | Permissible ambient temperature, ingress protection, insulation, cooling method, and mounting dimensions are model-specific ratings—not properties guaranteed by a 1.5 hp power rating. | Confirm the enclosure and cooling are suitable for the site, and check shaft and mounting dimensions against the driven equipment. Allow for any output derating required by the motor’s datasheet. |