| 01 | Design Service Life | 25-year target UV, thermal, electrical and mechanical ageing should be evaluated together. | IEC 62930; EN 50618; accelerated ageing methods specified by the applicable product standard. | Material datasheets, ageing test reports, warranty terms and production traceability. | Confirm that the 25-year statement is a documented design target rather than an unsupported marketing claim. |
| 02 | Rated System Voltage | 1,000 V DC or 1,500 V DC Selection must match the photovoltaic system architecture. | IEC 62930 and EN 50618 for photovoltaic cables; system design must also comply with local electrical codes. | Voltage rating printed on the cable, declaration of conformity and applicable certification documents. | Check that cable, connector and assembled harness ratings are consistent. |
| 03 | Ingress Protection | IP68 target for mated connector assemblies Protection level is valid only under the stated test conditions. | IEC 60529; connector-specific requirements under IEC 62852. | IP test report identifying connector type, mating condition, immersion depth and test duration. | Do not treat an IP68 rating for an unmated or differently configured connector as equivalent. |
| 04 | Ampacity — 4 mm² Conductor | Typically about 30–40 A Actual current depends on insulation, ambient temperature, grouping and installation method. | IEC 60287 calculation principles and the applicable cable installation code. | Current-carrying-capacity table with derating factors and conductor resistance data. | Compare ampacity using the same ambient temperature, cable spacing and mounting conditions. |
| 05 | Ampacity — 6 mm² Conductor | Typically about 40–55 A Values must be confirmed for the selected cable construction and installation environment. | IEC 60287 calculation principles and relevant national installation requirements. | Conductor cross-section report, resistance at 20 °C and thermal derating curves. | Higher nominal cross-section does not automatically guarantee higher allowable current in every installation. |
| 06 | Contact Resistance | Low and stable throughout testing The exact limit must follow the connector specification and certification file. | IEC 62852 connector performance testing; manufacturer-approved mating components should be used. | Initial and post-ageing contact-resistance results, crimp cross-section records and pull-force data. | Check for resistance increase after thermal cycling, humidity exposure and mechanical stress. |
| 07 | TÜV Certification Evidence | Valid certificate for the exact product configuration | Relevant TÜV certification scheme together with IEC 62930, EN 50618 or IEC 62852, as applicable. | Certificate number, scope, model list, certificate holder, validity status and surveillance information. | Verify that the certificate covers the actual cable size, connector combination and assembly process. |
| 08 | Thermal Cycling and Humidity | Performance retained after environmental ageing No unsafe insulation damage, sealing failure or unacceptable resistance rise. | Applicable IEC/EN photovoltaic cable and connector test sequences, including thermal cycling and damp heat where specified. | Full test conditions, cycle count, temperature range, humidity level and before/after measurements. | Review failure criteria, not only a pass statement. |
| 09 | UV, Ozone and Outdoor Durability | Suitable for continuous outdoor PV exposure | EN 50618 and applicable material-resistance test methods for photovoltaic cable insulation and sheathing. | UV exposure report, ozone-resistance results, material formulation and outdoor-use declaration. | Confirm compatibility with rooftop heat, sunlight, moisture, wind movement and chemical exposure. |
| 10 | Crimping and Quality Control | Controlled, repeatable and traceable assembly | Connector manufacturer crimp specifications, IEC 62852 requirements and documented process controls. | Crimp-height records, pull-test frequency, conductor-strip inspection, torque records and batch traceability. | Assess whether production controls cover every cable size and connector combination supplied. |